Leave Us a Message

* Note: Please fill in the information accurately and keep communication open. We will contact you as soon as possible.

Submit
+
  • 7(1793008838167).jpg

Medium-Voltage Power Conversion System (PCS Integrated Unit)

Reliable dual-power design for the auxiliary power supply;

WhatsApp:

  • Product Description
  • Product Features

    ■ Reliable dual-power supply design for the auxiliary power system;

    ■ Three-level topology, with a maximum efficiency of 99%;

    ■ Intelligent multi-stage fan speed control, with wide-temperature operating capability;

    ■ Wire-free voltage-source parallel operation technology, supporting unlimited parallel connection of multiple units;

    ■ High protection rating (IP65, C5 optional)

    ■ Three-level topology, with a maximum conversion efficiency of 99%;

    ■ Equipped with functions such as PQ, VF, SVG, and VSG;

    ■ Operates in all four quadrants and features battery charge–discharge management.

    Product Block Diagram

    Technical Specifications

    Product Specifications 2750kVA 3150kVA 3450kVA 4000kVA
    DC parameters
    Maximum DC Voltage 1500Vdc 1500Vdc 1500Vdc 1500Vdc
    DC operating voltage range 800~1500Vdc 920~1500Vdc 1000~1500Vdc 1160~1500Vdc
    Maximum DC current 3781A 3766A 3795A 3795A
    Automatic buffering function possessing possessing possessing possessing
    Communication parameters
    Rated output power 2750kW 3000kW 3450kW 4000kW
    Maximum output power 3025kVA 3465kVA 3795kVA 4400kVA
    Rated grid connection voltage 550Vac 630Vac 690Vac 800Vac
    Communication Access Method Three-phase three-wire Three-phase three-wire Three-phase three-wire Three-phase three-wire
    Permitted grid voltage range -15%~10% (range customizable) -15%~10% (range customizable) -15%~10% (range customizable) -15%~10% (range customizable)
    Rated grid frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
    Maximum output current 3176A 3176A 3176A 3176A
    Power factor / Adjustable range >0.99 (rated output power) / 0.8 (leading) - 0.8 (lagging) >0.99 (rated output power) / 0.8 (leading) - 0.8 (lagging) >0.99 (rated output power) / 0.8 (leading) - 0.8 (lagging) >0.99 (rated output power) / 0.8 (leading) - 0.8 (lagging)
    Total Harmonic Distortion of Current THDi <3% (rated output power) <3% (rated output power) <3% (rated output power) <3% (rated output power)
    Off-grid voltage accuracy 1% 1% 1% 1%
    Total Harmonic Distortion of Voltage (THDu) <1.2% (linear load) <1.2% (linear load) <1.2% (linear load) <1.2% (linear load)
    Off-grid output frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
    Overload capacity 110% overload 110% overload 110% overload 110% overload
    Transformer parameters
    Transformer rated power 2750kVA 3150kVA 3450kVA 4000kVA
    Voltage ratio 0.55/6~35kV 0.55/6~35kV 0.55/6~35kV 0.55/6~35kV
    Transformer Category Oil change / Dry change Oil change / Dry change Oil change / Dry change Oil change / Dry change
    Basic Parameters
    Maximum efficiency of the converter 0.99 0.99 0.99 0.99
    Protection rating C4/IP65 (C5 optional) C4/IP65 (C5 optional) C4/IP65 (C5 optional) C4/IP65 (C5 optional)
    Operating ambient temperature -35℃~60℃ (>50℃ derating) -35℃~60℃ (>50℃ derating) -35℃~60℃ (>50℃ derating) -35℃~60℃ (>50℃ derating)
    Relative humidity 0~100 (no condensation) 0~100 (no condensation) 0~100 (no condensation) 0~100 (no condensation)
    Cooling method Smart Air Cooling Smart Air Cooling Smart Air Cooling Smart Air Cooling
    Dimensions (W x D x H) 6058×2438×2896mm 6058×2438×2896mm 6058×2438×2896mm 6058×2438×2896mm
    Weight 1.5T 1.5T 1.5T 1.5T
    Maximum operating altitude 5000m (>2000m derating) 5000m (>2000m derating) 5000m (>2000m derating) 5000m (>2000m derating)
    Display LED, HMI LED, HMI LED, HMI LED, HMI
    Communication interface RS485/Ethernet RS485/Ethernet RS485/Ethernet RS485/Ethernet
    Communication protocol Modbus-RTU, Modbus-TCP/IEC61850/IEC104 Modbus-RTU, Modbus-TCP/IEC61850/IEC104 Modbus-RTU, Modbus-TCP/IEC61850/IEC104 Modbus-RTU, Modbus-TCP/IEC61850/IEC104
    Product Certification GB/T 34120, IEC 62477-1, IEC 61850, EN 61000-6-2, EN 61000-6-4 GB/T 34120, IEC 62477-1, IEC 61850, EN 61000-6-2, EN 61000-6-4 GB/T 34120, IEC 62477-1, IEC 61850, EN 61000-6-2, EN 61000-6-4 GB/T 34120, IEC 62477-1, IEC 61850, EN 61000-6-2, EN 61000-6-4

Keywords:

Get More Product Information for Free

* Note: Please fill in the information accurately and keep communication open. We will contact you as soon as possible.

Submit

Related Products


WTD-10/630A High Voltage Load Switch

WTD-10/630A High Voltage Load Switch

BHA-10/630A Export Type Isolating Switch

BHA-10/630A Export Type Isolating Switch

YB Prefabricated Substation

The B series prefabricated substation is used in 6KV and 10KV ring network power supply, dual power supply, or terminal power supply systems, serving as high-voltage distribution metering, compensation control, and protection device.

YB M/YB P Prefabricated Substation

The YBM and YBP series prefabricated substations are compact complete power distribution units that combine high-voltage electrical equipment, transformers, and low-voltage electrical equipment.